01SCIP Engineering · With Fortified Structural Solutions

SCIP Engineering, 50% Off Your First Plan Set

SunSmart Engineering and Fortified Structural Solutions work together to make SCIP buildings simpler to engineer and permit. Send us your SCIP project and get 50% off your first plan set, up to $500 off.

01

Claim your offer

SunSmart + Fortified
50% off

Your first SCIP plan set with SunSmart Engineering, up to $500 off.

Fill out the form and our team will reach out to get your project started.

02

What we engineer for SCIP.

01
Structural design

Walls, floors and roofs sized for the actual loads, with the load path checked from the roof down to the foundation.

02
Sealed drawings

A permit-ready set of calculations and drawings, signed and sealed for the jurisdiction.

03
Wind load analysis

Design wind pressures per ASCE 7 for the exact address, exposure and risk category.

04
Plan review support

Many reviewers have not seen SCIP before. When they comment, we answer with revised details or added calculations.

03

What to send to start.

Complete information at the start is what keeps a SCIP project moving. This is what we ask for.

Site address and building department

They set the design wind speed, exposure and the code edition that applies.

Current architectural set

Openings, spans and roof shape drive the structural design.

Building use, survey and soils

Use sets the risk category and floor loads. Send any survey or soil report you have.

Panel takeoff or FortiPlan file

The panel types and layout from Fortified.

+FAQ

SCIP engineering questions.

Have a different question?

SCIP stands for structural concrete insulated panel. Fortified Structural Solutions' panels have a foam core with welded wire mesh on both faces, joined by cross wires that pass through the foam. Concrete is sprayed onto both faces on site, and the concrete and steel carry the load.

Yes. Fortified's ICC-ES evaluation report (ESR-5623) calls for an engineered design for each building, and that includes homes built under the residential code. We prepare the calculations and sealed drawings the building department reviews.

No. Wind loads are calculated for each building under ASCE 7, using the design wind speed, exposure and risk category for the address. That is the same approach as any engineered structure.

Tell us at intake. The Florida supplement to the current evaluation report does not cover the High-Velocity Hurricane Zone, so we review the approval path for those projects with you before we start.

Fill out the form on this page. Your first SCIP plan set with SunSmart Engineering is 50% off, with a maximum discount of $500.

Yes. We serve contractors across the U.S. and in the Caribbean. For a job outside Florida, tell us the governing code and the design wind speed if the local building department has given you one.