How SCIP works as a structure.
Concrete is sprayed onto each side of the panel on site. The concrete and steel carry the load.
Welded wire mesh on both faces, joined by cross wires through the foam, so the two faces work together.
Insulation, and a form to spray against. It holds nothing up.
Walls, floors and roof use the same panel system, tied together with mesh and finished in concrete.
What is in the package.
Every SCIP package is built to be read by a plan reviewer who may not have seen SCIP before, and followed by a crew in the field. We confirm the exact contents with you before we start.
Walls for wind and gravity loads, floors and roofs for span and load, and bracing walls for sideways loads, following ACI 318 and Fortified's ICC-ES evaluation report.
Design pressures per ASCE 7 for the exact address, exposure category, building height and risk category.
Dowels at the foundation, floor-to-wall ties, corner mesh, panel seams and reinforcement around openings, designed for the actual loads.
Shoring requirements for floors and roofs until the concrete has cured, and the special inspections the code requires for the mesh and sprayed concrete.
A permit-ready set sealed for the jurisdiction. Our Florida engineering firm authorization is COA35170.
When the reviewer comments on our sheets, we respond with revised details or added calculations.
Who this is for.
New homes and buildings framed in SCIP that need a sealed structural set to get through permitting.
Projects weighing SCIP for hurricane and debris resistance who want the structure engineered from the start.
Design teams that want an engineer who knows the SCIP design rules to work alongside their plans.
Crews trained by Fortified who need engineering that matches the panels and details they build.
How it works.
Most of the work on your side is sending complete information at the start.
Site address, the current architectural set, the use of the building, any survey or soil report, and the panel takeoff or FortiPlan file from Fortified.
We set the wind speed, exposure, risk category, soil assumptions and code edition for the address, and tell you what else we need.
We size the walls, floors and roof, design the connections, and check the load path from the roof down to the foundation.
You receive the sealed drawings and calculations, ready to submit with your permit application.
If the building department comments on our sheets, we answer with revised details or added calculations.
Codes and approvals involved.
SCIP plans are reviewed against the evaluation report, the concrete code and the wind criteria in force where the permit is filed.
Fortified's evaluation report. It sets the SCIP design method, its limits and the typical details, with Florida and California supplements.
SCIP is designed as reinforced concrete. Bracing walls are designed as special reinforced concrete structural walls, limited to Seismic Design Categories A and B.
Design wind speed, exposure category and risk category drive the pressures on the walls, roof and connections. We set them for the exact address.
SCIP is not a prescriptive system under the residential code. A home built with SCIP needs an engineered design.
The evaluation report lists one-hour wall and floor or roof assemblies. To claim the rating, build the assembly the way it was tested.
The HVHZ is Miami-Dade and Broward. The Florida supplement to the current evaluation report does not cover it, so tell us at intake if your site is there.
Common misconceptions.
The foam holds nothing up. The concrete and steel on both faces carry the load.
It doesn’t. Wind is worked out for each building and address.
Windows, doors and pipes through the wall need their own design, with reinforcement where the load concentrates.
Every SCIP building needs an engineered design, even under the residential code.
SCIP stands for structural concrete insulated panel. Fortified Structural Solutions' panels have a foam core with welded wire mesh on both faces, joined by cross wires that pass through the foam. Concrete is sprayed onto both faces on site, and the concrete and steel carry the load. The foam is insulation and a form to spray against.
Yes. Fortified's ICC-ES evaluation report (ESR-5623) calls for an engineered design for each building, and that includes homes built under the residential code. The building department reviews the sealed calculations and drawings before it issues the permit.
No. Wind loads are calculated for each building under ASCE 7, using the design wind speed, exposure and risk category for the address. The engineer checks the walls, roof and connections against those loads.
Yes. SCIP walls are designed as reinforced concrete shear walls, the walls that keep a building from racking sideways. The evaluation report limits this to areas with low earthquake risk (Seismic Design Categories A and B), and each bracing wall has to be a little longer than it is tall.
Not yet. Today every SCIP building is calculated from the evaluation report's design method. We are building load and span tables, a SCIP home calculator and a library of standard details with Fortified, coming soon.
Only the assemblies that were tested. The evaluation report lists a one-hour wall and a one-hour floor or roof, each with a specific concrete thickness and strength. A wall built with thinner concrete is not the tested assembly.
Tell us at intake. The Florida supplement to the current evaluation report does not cover the High-Velocity Hurricane Zone, so we review the approval path for those projects with you before we start.
The Florida Building Code, 8th Edition (2023) applies through December 30, 2026, and the 9th Edition (2026) is scheduled to take effect December 31, 2026. Check which edition your permit application falls under. Outside Florida, we design to the code your jurisdiction has adopted.
Get Started
New to SunSmart? Your first SCIP plan set is 50% off, up to $500 off. Send the site address, the plans and the panel layout, and we will confirm the scope. You can also call 866-SUN-8655 or email solutions@sunsmartengineering.com.